Fuel cell technologies - Part 3-201: Stationary fuel cell power systems - Performance test methods for small fuel cell power systems
This part of IEC 62282 provides test methods for the electrical, thermal and environmental
performance of small stationary fuel cell power systems that meet the following criteria:
• output: rated electric power output of less than 10 kW;
• output mode: grid-connected/independent operation or stand-alone operation with singlephase
AC output or 3-phase AC output not exceeding 1 000 V, or DC output not exceeding
1 500 V;
NOTE The limit of 1 000 V for alternating current comes from the definition for "low voltage" given in
IEC 60050-601:1985, 601-01-26.
• operating pressure: maximum allowable working pressure of less than 0,1 MPa (gauge) for
the fuel and oxidant passages;
• fuel: gaseous fuel (natural gas, liquefied petroleum gas, propane, butane, hydrogen, etc.)
or liquid fuel (kerosene, methanol, etc.);
• oxidant: air.
ΚΩΔΙΚΟΣ ΠΡΟΪΟΝΤΟΣ:
CYS EN 62282-3-201:2017 (+A1:2022)
This part of IEC 62282 provides test methods for the electrical, thermal and environmental
performance of small stationary fuel cell power systems that meet the following criteria:
• output: rated electric power output of less than 10 kW;
• output mode: grid-connected/independent operation or stand-alone operation with singlephase
AC output or 3-phase AC output not exceeding 1 000 V, or DC output not exceeding
1 500 V;
NOTE The limit of 1 000 V for alternating current comes from the definition for "low voltage" given in
IEC 60050-601:1985, 601-01-26.
• operating pressure: maximum allowable working pressure of less than 0,1 MPa (gauge) for
the fuel and oxidant passages;
• fuel: gaseous fuel (natural gas, liquefied petroleum gas, propane, butane, hydrogen, etc.)
or liquid fuel (kerosene, methanol, etc.);
• oxidant: air.